Background Pathological crying has been rarely reported after deep brain stimulation. The exact neural substrate is unknown, but it is often assumed that pathological crying and the pseudobulbar syndrome result from disturbances of a common neural pathway.
Design Case report.
Setting Tertiary referral center for neurosurgery.
Patient A 48-year-old woman with advanced Parkinson disease who received bilateral implantation of deep brain stimulators in her subthalamic nuclei.
Results Stimulation in the region of the caudal internal capsule resulted in pathological crying but no other features of pseudobulbar palsy.
Conclusions At least 1 of the pathways controlling crying passes through the region of the caudal internal capsule, and this pathway is distinct from those involved with laughter and nonemotional facial movements. Moreover, different stimulation frequencies may elicit either crying or anxiety but not both.
Pathological crying (PC) is a disorder of emotional expression characterized by involuntary, recurrent bouts of crying that are incongruent with the prevailing emotional, cognitive, and social context and is not associated with a sensation of sadness.1 This condition may be accompanied by laughter (pathological laughter and crying [PLC]), which is assumed to share a common mechanism.1 - 2 Pathological laughing and crying are often included as part of a wider pseudobulbar syndrome that may include disturbances of swallowing, speech, bulbar function, and exaggeration of facial, palatal, and jaw reflexes.
Although PLC is frequently encountered in a variety of neurological disorders, reports of crying or laughing following stimulation of the thalamus,3 globus pallidus interna,3 subthalamic nucleus (STN),4 and substantia nigra5 are rare and have all been associated with an emotional component. Prior to this article, there has only been 1 other case of PC following deep brain stimulation (DBS) to our knowledge.6 In that article, PC, slurring of speech, and exaggeration of facial and gag reflexes were observed with monopolar stimulation through contacts extending from the subthalamus to the thalamus. We report a case where high-frequency stimulation via a single contact in the region of the caudal internal capsule (CIC) resulted only in PC. This very localized effect argues for a distinct neural pathway for PC, separate from the larger constellation of symptoms that occur in PLC or the pseudobulbar syndrome.
A 48-year-old, left-handed woman with a 9-year history of Parkinson disease presented with severe motor fluctuations and disabling dyskinesias despite receiving 1150 mg of levodopa, 1200 mg of entacapone, 5 mg of selegiline hydrochloride, and 6 mg of pramipexole dihydrochloride daily. Structured preoperative neuropsychiatric evaluation and brain imaging revealed no cognitive, mood, or psychiatric disturbances or structural lesions. Preoperative Unified Parkinson Disease Rating Scale motor subscale scores while receiving and not receiving medication were 52 and 13, respectively. She underwent bilateral insertion of STN electrodes (Medtronic 3389; Medtronic, Inc, Minneapolis, Minnesota). The targets were selected from axial fast short time inversion recovery magnetic resonance images and adjusted intraoperatively following microelectrode recordings and macroelectrode stimulation. Approaching the left target (x, y, z = −13.7 mm, −1.3 mm, −6.1 mm, respectively), microelectrode recordings characteristic of the STN were encountered from 2 mm above the target (t = −2) to 3 mm below it (t = +3) and the substantia nigra from t = +4.5. There was significant clinical improvement during macrostimulation. The most distal contact was placed at t = +3. The right STN electrode was implanted in a similar manner. Electrode contacts were numbered 0 to 3 from deep to superficial on the right and 4 to 7 from deep to superficial on the left.
Stimulation titration began 6 weeks postoperatively with the patient not receiving medication for at least 12 hours. The patient began to cry uncontrollably within seconds of monopolar stimulation (0.5 V, 60 microseconds, 130 Hz) involving contact 6 (x, y, z = −11.5 mm, −3.8 mm, −12.2 mm, respectively). This occurred even when parameter changes were visibly concealed from the patient. Sham testing did not elicit a similar response. The patient did not know why she was crying and could not stop herself from crying. There was no sensation of sadness, pain, or persecution. Crying stopped within 5 seconds of stimulation cessation. Similar responses were observed with bipolar stimulation through contacts 6 (cathodal) and 7 (anodal) at amplitudes of 1.0 V or greater. The Beck Depression Inventory score before and during monopolar stimulation of contact 6 was 10 (0-10 being normal, with scores > 10 indicative of increasing mood disturbance). Stimulation through other contacts did not elicit a similar response. Interestingly, the patient became anxious but did not cry when monopolar stimulation at a frequency of 50 Hz via contact 6 or 7 (0.5 V, 60 microseconds) was applied. As the frequency increased, anxiety was replaced by an urge to cry; however, crying only occurred when the frequency equaled or exceeded 130 Hz. The patient did not experience anxiety when she cried unless the episode was prolonged. She had no pseudobulbar symptoms during or immediately after episodes of stimulation-induced crying. Postoperative magnetic resonance imaging showed that contacts 6 and 7 were in the region of the CIC on the left (Figure), with contacts 4 and 5 just within the dorsolateral STN (not shown).
Composite preoperative and postoperative magnetic resonance imaging scans showing the location of contact 6 (white dot) in the axial (A), coronal (B), and sagittal (C) planes. The Schaltenbrand-Wahren electronic stereotactic atlas is superimposed on the image. Contact 6 is within the internal capsule. The hypointense areas around the contact are artifacts due to the metal electrodes. R indicates right; L, left; ANT, anterior; POS, posterior; TH, thalamus; GPI, globus pallidus interna; and STN, subthalamic nucleus.
The patient's parkinsonian symptoms improved with monopolar stimulation through contact 4 (x, y, z = −11.5 mm, −2.7 mm, −9.6 mm, respectively) on the left (2.0 V, 60 microseconds, 130 Hz) and contact 3 on the right (1.6 V, 60 microseconds, 130 Hz). Two years after surgery, her Unified Parkinson Disease Rating Scale motor subscale score was 4, the dyskinesias had completely resolved, and the levodopa dose had been reduced by 80%. The postoperative magnetic resonance imaging scan showed that the chronic stimulating electrodes were within the dorsolateral STN (not shown).
Wilson2 hypothesized that a brainstem fasciorespiratory center coordinates the action of several systems involved in emotional expression. Descending pathways from undefined cortical centers to the fasciorespiratory center2 and modulatory input from the cerebellum7 are believed to be important in the control of voluntary and involuntary expression of emotion. It is thought that PLC results from the uncoupling of the fasciorespiratory center from cortical (voluntary pathway) or cerebellar influences, and it has been associated with lesions in the cortex, striatocapsular region, mesencephalon, brainstem, and cerebellum.8 Lesions causing PLC are usually bilateral and almost always result in other features of brainstem dysfunction.1 This has led to the suggestion that PLC and the pseudobulbar syndrome result from disturbances of a common neural pathway.1 However, PLC has rarely occurred without associated emotions or pseudobulbar symptoms.9 - 10 To date, the actual neural pathway involved in PLC is unknown but the internal capsule is almost always involved.1
Our case confirms that PC can exist in the absence of other pseudobulbar symptoms, suggesting that separate neural pathways exist for the control of crying, laughing, and bulbar movements at least in the region of the CIC. Further subdivision of this pathway may also be present because negative emotional responses (anxiety or crying) but not positive ones (laughing) could be produced by altering the stimulation frequency. Frequency-dependent neural modulation has been shown to be responsible for alterations in verbal fluency and motor symptoms due to the activation of different neural pathways in patients with STN-DBS.11 Our case suggests that it may also affect the expression of different aspects of negative emotional responses.
A weakness of our study is our inability to determine the actual neural substrate that caused PC. Structures in the region of the CIC include the subcortical gray matter (basal ganglia, hypothalamus, thalamus, STN, substantia nigra) and fibers connecting the cortex, subcortical gray matter, and brainstem structures such as the corticobulbar and spinal tracts, zona incerta, and medial forebrain bundle. The magnetic resonance imaging scan shows that contact 6 lies within the posterior limb of the CIC without touching the surrounding deep gray matter (Figure). Experimentally, the current spread around a monopolar electrode at 1.0 V is approximately 2.5 mm.12 The degree of current spread around the monopolar electrode causing PC at 0.5 V would be expected to be less than 2 mm. A current density sphere with a radius of 2 mm would be largely confined to the white matter in the region of the CIC. This, together with the fact that large myelinated axons have a lower firing threshold than local cells13 and are more likely to be stimulated at 0.5 V, suggests that the effects of stimulation in our case must be mediated through fiber tracts. In the other reported case of PC after DBS, higher stimulation amplitudes (1.5 V) and pulse widths (90 microseconds) through all of the contacts extending from the subthalamus to the thalamus were used, and the patient had slurred speech and hyperactive facial and gag reflexes.6 This was absent in our patient and suggests that the PC seen in the study by Okun et al6 resulted from stimulation of surrounding white matter tracts (which includes the CIC) due to the greater current spread.
There is no strong evidence to suggest that the placement of the contralateral electrode predisposes to the development of PC. Most STN-DBS electrodes are implanted bilaterally, yet PC after DBS is extremely rare. In the only other reported case of PC after STN-DBS, only 1 electrode was implanted, and this was on the same side as a previous pallidotomy.6 In addition, PLC has been reported after unilateral strokes.14 - 15
Finally, it has been suggested that the optimal electrode position for subthalamic DBS is in the zona incerta and upper STN region,16 and there has been a recommendation to insert electrodes more dorsally to avoid STN-induced mood disorders.17 However, clinicians should be aware that more dorsally located stimulation may potentially result in PC.
Correspondence: Christopher R. Honey, MD, DPhil, FRCS(C), Surgical Centre for Movement Disorders, University of British Columbia, 8105-2775 Laurel St, Vancouver, BC V5Z 1M9, Canada (chris.honey@telus.net).
Accepted for Publication: April 12, 2007.
Author Contributions:Study concept and design: Low. Acquisition of data: Low. Analysis and interpretation of data: Low, Sayer, and Honey. Drafting of the manuscript: Low and Honey. Critical revision of the manuscript for important intellectual content: Low, Sayer, and Honey. Administrative, technical, and material support: Low, Sayer, and Honey. Study supervision: Honey.
Financial Disclosure: None reported.
Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature
Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal
Instructions
Comments are moderated and will appear on the site at the discretion of the Archives of Neurology editors. Comments should not exceed 500 words of text and 10 references.
Do not submit personal medical questions or information that could identify a specific patient, questions about a particular case, or general inquiries to an author. Only content that has not been published, posted, or submitted elsewhere should be submitted. By submitting this Comment, you and any coauthors transfer copyright to the journal if your Comment is posted.
* = Required Field
Disclosure of Any Conflicts of Interest* Indicate all relevant conflicts of interest of each author below, including all relevant financial interests, activities, and relationships within the past 3 years including, but not limited to, employment, affiliation, grants or funding, consultancies, honoraria or payment, speakers’ bureaus, stock ownership or options, expert testimony, royalties, donation of medical equipment, or patents planned, pending, or issued. If all authors have none, check "No potential conflicts or relevant financial interests" in the box below. Please also indicate any funding received in support of this work. The information will be posted with your response.
Register and get free email Table of Contents alerts, saved searches, PowerPoint downloads, CME quizzes, and more
Subscribe for full-text access to content from 1998 forward and a host of useful features
Activate your current subscription (AMA members and current subscribers)
Some tools below are only available to our subscribers or users with an online account.
Download citation file:
Web of Science® Times Cited: 5
Customize your page view by dragging & repositioning the boxes below.
The Rational Clinical Examination Evidence Summary and Review 2
The Rational Clinical Examination EDUCATION GUIDESOtitis Media, Child
All results at JAMAevidence.com >
and access these and other features:
Register Now
Enter your username and email address. We'll send you a reminder to the email address on record.
Athens and Shibboleth are access management services that provide single sign-on to protected resources. They replace the multiple user names and passwords necessary to access subscription-based content with a single user name and password that can be entered once per session. It operates independently of a user's location or IP address. If your institution uses Athens or Shibboleth authentication, please contact your site administrator to receive your user name and password.